Home > Products > Specifications > Murus MMR-2100PUR
Murus MMR-2100PUR
|
THE MURUS MMR-2100PUR INSULATING PANEL |
|||
| # | 2145 | 2155 | 2165 |
|
Overall Thickness: |
4-5/8" | 5-5/8" | 6-5/8" |
|
Thickness Tolerance: |
+/- 1/8" | * | * |
|
Width: |
48" | * | * |
|
Width Tolerance: |
+0"-1/8" | * | * |
|
Standard Lengths: |
8,9,10,12,14' | * | * |
|
Length Tolerance: |
+/- 1/4" | * | * |
|
Weight: |
4.05 lb/sf | 4.25 lb/sf | 4.45 lb/sf |
|
Insulating Core |
|||
|
Type: |
Polyurethane closed cell foam | ||
|
Thickness: |
3-11/16" | 4-11/16" | 5-11/16" |
|
Density: |
2.2 lb/cu.ft. | * | * |
|
R-value |
6.76 per inch thickness | * | * |
|
Insulating Core Properties |
4Design Values |
||
|
K Factor: |
.148 | ASTM C-518 | |
|
Compressive Strength: |
23 psi | ASTM D-1621 | |
|
Compressive 1MOE: |
682 psi | ASTM D-1621 | |
|
Shear Strength: |
31 psi | ASTM C-273 | |
|
Shear Modulus: |
203 psi | ASTM C-273 | |
|
Flexure |
52 psi | ASTM C-203 | |
|
Flexure Modulus |
587 psi | ASTM C-203 | |
|
Tensile Strength: |
37 psi | ASTM D-1623 | |
|
Tensile Modulus: |
611 psi | ASTM D-1623 | |
|
WVT/ |
1.0 | ASTM E-96 | |
|
Foam Fire Rating: |
Class 1 | **UL723 | |
|
Flame Spread: |
20 | **UL723 | |
|
Smoke Developed |
300 | **UL723 | |
|
1MOE: Modulus of Elasticity 2MOR: Modulus of Rupture 3MD: Machine Direction 4Design Values are mean derived from multiple specimens |
|||
|
Outside Skins |
|||
|
Exterior: |
APA or equivalent listedoriented strand board (OSB) meeting PS 2-04 requirements |
||
|
Grade: Exposure-1 |
|||
|
Thickness: 7/16" |
|||
|
Interior: |
Gypsum Wall Board |
||
|
Type: Moisture and Mold Resistant |
|||
|
Thickness: 1/2" |
|||
|
1 Structural Design Guidelines |
|||
|
Roof Spans: |
Vertical or horizontal spans not to exceed 4' |
||
|
*Wall Spans: |
Unsupported vertical or horizontal spans not to exceed 8' |
||
|
1Structural design guidlines for reference only; product capabilities may be greater than, or less than listed depending on panel thickness and/or local or regional loads. |
|||
|
*The Company does not recommend nor warrant this product for use in wall applications. |
|||
| For additional design information, contact The Murus Company, Inc. | |||