What is the difference between a “stress skin” panel, a “foam core sandwich” panel, and a “structural insulating” panel?

The terms “stress skin”, “foam core sandwich”, and “structural Insulating” panels (SIPs) all refer to the same product and are interchangeable.  The industry terminology has standardized and the term “SIPs” is most often used among panel manufacturers. However, “stress skin panels” and “foam core sandwich” panels are still popular terms among timber frame professionals.

Is there any danger of off-gassing?

Murus EPS foam does off-gas when it is manufactured; however, it is inert by the time it reaches our facility before it is manufactured into SIPs. Construction materials of more immediate concern for off-gassing would be pressboard as is found in countertops, underlayment and cabinet backs, and carpeting, for example.

How is wiring accomplished in Murus SIPs?

If ordered, Murus cuts in horizontal electrical chase(s) through the panel cores.  The chases are located in the center of the foam and are typically at standard horizontal heights for outlets, depending on how the panels are ordered. In some cases, you may have to do some pre-wiring before the panels are installed and during the installation process, but often the majority of the wiring can be accomplished after the panels are installed.

How is plumbing accomplished in Murus SIPs?

Good building practices will keep plumbing out of exterior walls. Most SIP home designs incorporate plumbing into interior partition walls.

What can be done to insure the indoor air quality of my Murus SIP home?

Indoor air quality has become a major health concern in homes and buildings that are built to meet or exceed today’s energy conservation codes. A structure that is properly built with SIPs can be very airtight, so many manufacturers, including Murus, require the inclusion of a mechanical ventilation system into your heating and/or cooling system. Typically this is done through a Heat Recovery Ventilator (HRV) or an Energy Recovery Ventilator (ERV). Most of the major HVAC system manufacturers now offer these units, as do many smaller companies, so consult with your mechanical contractor. Learn more: Mechanical Ventilation

How strong is the Oriented Strand Board (OSB) used in SIPs?

OSB has come a long way since it was first introduced. The OSB used in the manufacture of SIPs is quite different from a lot of the material used for wall and/or roof sheathing because the wood fibers are oriented in a way that gives the board more than adequate strength for satisfactory performance. The strength and integrity of the OSB is fully tested and documented by the manufacturer and other agencies.

How are kitchen cabinets and other wall elements mounted?

Standard installation procedure of screwing the cabinets to the walls is usually acceptable, although you may want to use a few more screws. Excessively heavy items may require readily available specialty fasteners. Consult with the cabinet manufaturer for recommendations.

How are Murus SIPs installed?

In structural applications, SIPs are typically installed over a 2x plate that is attached to the sill or subfloor. The foam is removed from between the skins so the panel sits over the 2x and nails and/or screws are driven through the skins into the 2x. Usually a double 2x top plate is installed in the same manner. There are many variations on these procedures.

Murus recommends a cold roof. What is that?

If you use SIPs for the roof, Murus has always felt that a “cold” roof, or vented roof on top of the panels, is the best application. Typically this is accomplished by first installing 15-pound roofing felt on the roof panels, then installing 1x or 2x lumber vertically from the eaves to the ridge. These “straps” are put on 16” or 24” centers and sheathing (OSB or plywood) is attached over it before the roofing material is applied. The eave is left open or vented through the soffit, and the ridge is vented with a vent cap.

Does the EPS foam contain formaldehyde?

No.

How do I protect my Murus SIPs from insects?

No matter what type of home you are building, whether a SIP home or a conventional stick construction home, it is recommended that a regular preventive program of insect treatment be initiated and maintained when building in a known insect risk area.  Most pest control companies offer maintenance plans, renewable periodically or annually, and will automatically treat your grounds and structure at pre-determined intervals. With such a program and proper maintenance of the property, you should be able to comfortably minimize the risk of insect infestation.

What does a “Class 1 Fire Resistance Rating” mean?

Murus EPS SIPs conform to test standards set by the American Society for Testing and Materials (ASTM E-84) for acceptable flame spread and smoke development for combustible construction materials. ASTM E-84 is a similar test to UL-723, NFPA 2255, or UBC 8-1. Testing is accomplished by suspending a sample of material in the tunnel of a horizontal test chamber. The material is exposed to gas flame on one end of the tunnel for 10 minutes. The flame progression on the material is compared to selected standards and calculations made to produce a flame spread rating. Smoke from the fire in the tunnel is measured in the exhaust stack via a light beam to establish smoke developed ratings. There are three classes of acceptability for rigid foam used in construction: Class 3 is unacceptable, Class 2 is the minimum standard required for residential construction, and Class 1 is the best classification available. The EPS cores of Murus Sips have a Class 1 Fire Resistance Rating.

 
The Murus Company, Inc.
PO Box 220 • 3234 Route 549 • Mansfield, PA • 16933
Phone: 570-549-2100 Fax: 570-549-2101
Email:
© Copyright 1998-2008 The Murus Company, Inc.
Mansfield, Pennsylvania USA.
All rights reserved worldwide
Website by Artimbo
 
Structural Insulated Panel Association
Timber Frame Builders Council
Nationaly Association of Home Builders
GreenSpec Listed